(((AWA))) Alpha Wireless Automation Inc

Alpha Wireless Tank Monitoring System

The  Digital Cellular Pressure Monitor measures and reports the inventory status of product in remote storage tanks. It’s battery-powered and completely wireless. Tank data is transmitted directly from the tank to the  Data Center using GSM or CDMA cellular technology. The Digital Cellular Pressure Monitor is a simple, cost-effective solution for remote level measurement in storage tanks up to 60 feet in depth.

Set up:

  • Set up the tank dimensions, measurement schedule, report schedule and alarms from your office. There’s no configuration necessary at the tank site.
  • Drop the sensor in the tank and turn it on. There’s no need to open the monitor to initiate operation.
  • A text message is sent to the installer’s cell phone to confirm
    system operation, set up parameters, cellular reception
    strength, and inventory on hand so that operation is verified
    before leaving the site.
  • The monitor has integral 1-1/2" and 2" NPT threads to fit
    most tanks without additional hardware.
Measurement:
  • A level measurement is taken immediately before data transmission so the most up to date information is always displayed.
  • Measurements can be scheduled for once every 5 minutes to once per day.
  • The measurement schedule can be revised at any time from your  Data Center account to optimize system performance.
  • Each measurement includes fluid level, fluid temperature, battery strength, and radio field strength.
Alarms:
  • Two set point alarms are used to send an immediate report when the tank level gets below or above the limits that you set. Use them to alert when a delivery or pickup is needed.
  • The monitor reports immediately when any alarm condition is detected.
  • Email, fax, or text message alerts can be sent automatically so you are always alerted when a critical condition exists.
Reports:
  • Schedule tank reports for when you need them.
  • Select from one report per day to 9 reports per day.
  • Select the time of day you want to receive your reports.
  • Change the report schedule anytime from your Centeron Data Center account.
  • The monitor reports immediately when any alarm condition occurs.
  • Tank depth : 20 ft.
  • Operating Temperature: -22° F to +160° F
  • Battery Life: 2 years
  • Enclosure: UL 50 Type 4 - 4.28 Dia. X 7.32 Ht.
  • Integral 1-1/2" and 2" NPT mounting threads
  • Certified to UL 61010B-1 and CAN/CSA-C22.2 No. 61010.1-04
  • FCC Part 15 approved
  • Coverage in the U.S., Canada, and Mexico on all GSM networks
    Call 1-877-292-8770 and speak directly to a Alpha Wireless
    applications engineer


Contact Information

Tel: 310-488-4249 or toll free 877-292-8770
Fax: 213-232-3233
Postal address
11271 South Robertson Blvd, Suite 134
           Los Angeles, CA 90035
Electronic mail
General Information: info@RemoteTank.com
Sales: georgew@RemoteTank.com